Advantage:
• Guaranteed to last longer
• True MERV 8 maintained efficiency
• Meets all published hospital filter efficiency guidelines
Description: High capacity pleated panel filter available in 1", 2" or 4" depths.
Typical applications: Prefilters to higher efficiency filters, stand-alone filter for rooftops, split systems, free-standing units and package systems and air handlers.
Efficiency: Value of 8 for MERV and MERV-A when evaluated under ASHRAE Testing Standard 52.2.
Media: Proprietary blend of cotton and synthetic fibers in a uniform lofted media blanket.
Recommended final pressure drop: 1.0" w.g. when operated at 500 fpm. System design may dictate alternative changeout point.
Temperature: Maximum continuous operating temperature of 200º F (93° C).
Ratings: ECI value of five stars, listed as UL 900.
See Literature 1002 for more details.
Pre-Filtration: G2 to G4

Glaoigh orainn

Advantage:

• Guaranteed to last longer

• True MERV 8 maintained efficiency

• Meets all published hospital filter efficiency guidelines

Description: High capacity pleated panel filter available in 1", 2" or 4" depths.

Typical applications: Prefilters to higher efficiency filters, stand-alone filter for rooftops, split systems, free-standing units and package systems and air handlers.

Efficiency: Value of 8 for MERV and MERV-A when evaluated under ASHRAE Testing Standard 52.2.

Media: Proprietary blend of cotton and synthetic fibers in a uniform lofted media blanket.

Recommended final pressure drop: 1.0" w.g. when operated at 500 fpm. System design may dictate alternative changeout point.

Temperature: Maximum continuous operating temperature of 200º F (93° C).

Ratings: ECI value of five stars, listed as UL 900.

See Literature 1002 for more details.

Pre-Filtration: G2 to G4

Technical specaitheasc:

1.Material: Made of galvanized steel sheet.2.Fan: Japanese Nidec EC motor + original importedtechnical metal impeller.The impeller is backwardinclined type with thermal protection grade P44.Each unitundergoes balancing test prior to leaving factory, withimpeller dynamic balance grade of G2.5.3.Equipped with efficient filter without partition aluminumframe (1170*570*69) with filtering efficiency of 100grade@0.3um and 99.995% H13 initial resistance of125Pa4Air velocity: 0.45-0.75m/s 5% air volume: 1000ma/hPower supply: 220V 50Hz.5.48-58dB +5dB (static test 1.5m below the efficientfilter).6.Rated power 36W102W+5W7.Vibration peak value: <5um.

Nótaí:

1.HEPA efficient filter.2.Galvanized steel sheet casing3.Group control box.4.Japanese Nidec Shibaura EC motor withoriginal metal impeller.5.220V/50Hz power interface.6.Metal protective net.7.Air collector.8.L ifting handle

Pleated Filters

Advantages Application: Primary filter for air conditioning systems. Type: High performance disposable pleated panel filter. Case: Rigid water resistant cardboard. Media: Mixture of cotton and synthetic fibre. EN779:2012 efficiency: G4. Gravimetric efficiency: 92%. Recommended final pressure drop: 250 Pa. Temperature: 70ºC maximum in continuous service. Holding frames: Front and side access housings and frames are available, Type 8, Type L, and FC Housings. D W H D EN 779:201 EN 779:2012 TESTED ACCORDING TO • Water resistant cardboard frame • Conception with girders/ crossbars • Diagonal stiffner stuck to media to keep the spacing of folds, protect and maintain the filter • Fully supported media bonded onto a wire support grid • Rounded pleats for a maximum capacity of dust retention and facilitate airflow through the media • Replaceable filter media

Application: Primary filter for air conditioning systems. Type: High performance disposable pleated panel filter. Case: Rigid water resistant cardboard. Media: Mixture of cotton and synthetic fibre. EN779:2012 efficiency: G4. Gravimetric efficiency: 92%. Recommended final pressure drop: 250 Pa. Temperature: 70ºC maximum in continuous service. Holding frames: Front and side access housings and frames are available, Type 8, Type L, and FC Housings.

Model Name Filter class Width Height Depth Airflow m3/h Pressure drop Pa Media area m2 Unit weight kg Unit volume m3 24241 G4 594 594 23 2600 65 0,83 0,5 0,01 24242 G4 594 594 48 3420 70 1,64 0,78 0,02 24244 G4 594 594 98 4140 90 2,56 1,45 0,04 12242 G4 289 594 48 1710 70 0,79 0,4 0,01 16202 G4 394 495 48 1890 70 0,94 0,44 0,01 16252 G4 495 622 48 2340 70 1,18 0,55 0,02 20202 G4 495 495 48 2340 70 1,12 0,55 0,02 20242 G4 495 594 48 2880 70 1,36 0,66 0,02 20252 G4 495 622 48 2970 70 1,42 0,7 0,02 12244 G4 289 592 98 2070 90 1,28 0,75 0,02 16204 G4 394 495 98 2250 90 1,45 0,85 0,02 20204 G4 495 495 98 2880 90 1,73 1,05 0,04

6361542912872215495053486

Engaged in creating a clean and fresh environment for people, Sffiltech is specialized in fan filter unit. As one of the best manufacturers and suppliers, we can assure you the best quality and stable performance of our custom products. Please rest assured to buy.
Hot Tags: ac filter spray cone air filter hvac air filters air cleaner filter

Catagóirí te