Hospital operating room to air filter requirements?
Create a comfortable environment conducive to work for medical staff, and meet the strict requirements of air temperature, humidity, wind speed, freshness and cleanliness, noise and so on during the operation. So, the surgery building has
The clean area, quasi-clean area and general area are strictly divided, with clear flow direction and rigorous plane function area.
Create a comfortable environment conducive to work for medical staff, and meet the strict requirements of air temperature, humidity, wind speed, freshness and cleanliness, noise and so on during the operation. So, the surgery building has
The clean area, quasi-clean area and general area are strictly divided, with clear flow direction and rigorous plane function area.
Air cfu/m3: ≤10 object surface cfu/cm3: ≤5 medical staff hand cfu/cm3: ≤5 With the continuous improvement and improvement of modern hospital conditions, environment and medical quality, layer
Flow equipment has gradually been equipped and applied to the hand room. The following is a brief introduction to the design concept of my company.
1 Flow floor operating room-Clean and comfortable working environment Laminar flow operating room adopts air cleaning technology to control microbial pollution to different degrees, so as to control the air cleanliness in the space environment
Requirements for various types of surgery; And provide appropriate temperature, humidity, to create a clean and comfortable operating space environment. Laminar flow operating room not only requires highly clean air (the air entering the operating room must first be purified by "Lingjie" brand high efficiency filter), but also requires that the flow direction of the air flow can be controlled (that is, the use of laminar flow ultra-clean device), so that the air flow from the high cleanliness of the operating area to the low cleanliness area, and take away and discharge
Dust particles (dust particles) and bacteria in the airflow; Laminar flow is a thin, thin layer of air flowing in the same direction at a uniform velocity. The direction of purifying air can be divided into vertical layer flow and horizontal layer flow
Two kinds. The Supply air ceiling for operating theatre is installed on the wall of the foot side of the operating patient, the air flow is blown horizontally, and the return air outlet is set at the opposite one
On the ceiling side to the wall. Generally, vertical layer flow is more effective.
Laminar flow operating room is a "positive pressure" environment. The air pressure varies according to the cleanliness requirements of different areas (such as operating room, aseptic preparation room, brush room, surrounding clean area, etc.). Don't
The air cleanliness standards of laminar flow operating rooms at the same level are different. For example, the U.S. federal standard for Level 100 laminar flow operating rooms is ≥0.5μm dust particles per cubic foot of air, ≤100 dust particles or per liter of air
Medium ≤3.5 pieces. Level 1000 refers to the number of dust particles per cubic foot of air ≥0.5μm, ≤1000 particles or ≤35 particles per liter of air. And so on.
Different levels of laminar flow systems also have different air displacement rates in the control space environment. The higher the cleanliness level, the faster the displacement rate, and vice versa.
The wall of laminar flow operating room should be painted with special antibacterial paint, which has bright light, soft color and does not need to be cleaned with water.
2. Functional characteristics of laminar flow operating room
2.1 Low bacterial count in the operating room.
2.2 Comfortable air flow (indoor temperature can be 15-25℃, humidity can be adjusted between 50-65%).
2.3 Positive pressure air flow (+23-25Pa) in the operating room to prevent the entry of external pollution.
2.4 The air in the operating room is fresh and clean, and the working environment is comfortable.
2.5 In laminar flow operating room, there is generally no need to use physical or chemical methods for disinfection, which not only saves labor, but also avoids the influence of bad gas.
2.6 The rate of nosocomial infection (especially in surgery and burns) has been significantly reduced.
2.7 Noise: Noise generated by the operation of the air processor (air supply, return, etc.) and air conditioning system of laminar flow equipment
Sound, as a kind of noise in laminar flow operating room, is also a major shortcoming of laminar flow operating room. Fortunately, the operating room volume is 42dB, but no discomfort; But the volume outside the operating room is more than 65dB, forming noise interference.
"The heart wants to be quiet and the sound is more than", a long-term place, there is a process of tolerance and adaptation